LEADING PROGRAMMING AND MEASUREMENT SOLUTIONS Trusted Shops Garantie
Acute DS-1202
Acute DS-1202 Acute DS-1202 Acute DS-1202

Acute DS-1202

PC based high quality 2 channel DSO with 200 MHz bandwidth, 200 MSa/s sample rate and 512 Kbit memory.

This article is no longer available. Alternative:
Acute TS2202E

2 years warranty

30 days trial period

Facebook Share
Google +1
Twitter

The Acute DS-1202 is a PC based dual channel oscilloscope. The device features a bandwidth of 200 MHz and a sampling rate of 200 MSa/s.

The DS-1202 is a full-fledged compact oscilloscope. It is controlled via a PC which also displays the measurement signals. The oscilloscope is connected to a PC directly via a USB connection.

  • Model
  • Bandwidth
    100 MHz
    200 MHz
    200 MHz
    200 MHz
  • Max. Sample rate
    100 MSa/s
    200 MSa/s
    200 MSa/s
    200 MSa/s
  • Memory (standard)
    64 Kbit
    64 Kbit
    512 Kbit
    2 Mbit
  • Video Trigger (NTSC, PAL, SECAM)
    OK
    OK

Special Features

Automatic  Measurements

Automatic Measurements

Various measurement values can be determine easily in realtime and displayed. Both cursor measurements and direct measurement with corresponding displays are available.

Possible measurements include frequency, period, max., min., high, and low voltages, Vpp, amplitude, Vrms, average voltage, as well as duty cycles and pulse widths for positive and negative signals.
Mathematical Functions

Mathematical Functions

The two channels can be linked through a variety of mathematical functions.
These channels can be added, subtracted, multiplied, and divided.
FFT (Fast Fourier Transformation)

FFT (Fast Fourier Transformation)

The Acute software can use “Fast Fourier Transformation” to analyze the frequency components of the measurement signal and display them graphically. That makes this device the ideal choice for analyzing noise components in DC supplies and other harmonic components.
Supported scales: Linear RMS, dbV RMS, dBm RMS
Supported windows: Rectangle, Blackman, Hanning, Hamming, Harris, Triangular, Cosine, Lanczos and Gauss
Extended Configuration

Extended Configuration

The display and the device measurement behavior can be controlled through the extended configuration. As an example, the channel colors and the print settings can be changed. It is even possible to give the channels individual names which are then shown on screen so that it is really easy to relate the trace to the measurement signal.
Comprehensive Exporting Options

Comprehensive Exporting Options

The recorded signal history can be exported to a large variety of file formats. This is especially useful for preparing reports, but the data can also be transferred as is for analysis in other programs. All settings can be saved in this manner as well.
Available formats: Hardcopy (direct printout), Word, Excel, CSV, Text, HTML and Screenshot in the intermediate clipboard.
Alarm Function for Triggering

Alarm Function for Triggering

The Acute DS-1000 can execute a program of choice for the first or every occurrence of a trigger event. This function is particularly useful for long term monitoring, where, as an example, a correctly set trigger could be used to detect faults and react accordingly.

Universal Software

The Acute logic analyzer software can also be used to control the DS-1000 series USB oscilloscopes from Acute. With the aid of an oscilloscope and logic analyzer, combined measurements can be taken and displayed together:

  • General Data
    PC USB DSO Acute DS-1202
  • Interfaces
    USB (High Speed), LAN
  • Dimension (WxHxD)
    80 mm × 27 mm × 136 mm
  • Parallel operation
    3 devices can be operated in parallel with one computer and one instance of the software (corresponds to 6 channels).
  • Warranty
    2 years
  • Weight
    253 g
  • Supported operation systems
    Windows 7 (32Bit + 64Bit), Vista (32Bit + 64Bit),
    XP (32Bit + 64Bit), Windows 2000, ME, 98SE
  • Oscilloscope Functions
    PC USB DSO Acute DS-1202
  • Channels
    2
  • Sampling Rate
    200 MSa/s realtime
  • Bandwidth
    200 MHz
  • Sampling mode
    Normal, average, peak detect
  • Mathematics
    A+B, A-B, A×B, A/B, FFT (Fast Fourier Transform)
  • FFT windows
    Rectangle, Blackman, Hanning, Hamming, Harris, Triangular, Cosine, Lanczos, Gauss
  • Signal
    PC USB DSO Acute DS-1202
  • Input
    DC/AC Coupling, to 42 Vpk (DC + AC peak)
  • Sampling Rate
    1 Sa/s to 200 MSa/s realtime
  • Time base
    2 ns/Div. to 10 s/Div.
    (Steps 1 - 2 - 5)
  • Memory
    512 Kpts / channel
  • Vertical
    PC USB DSO Acute DS-1202
  • Analog digital converter (A/D)
    2 mV/Div: 8Bit per channel
    5 mV/Div to 10 V/Div: 9 Bit per channel
  • Sensitivity range (V/div)
    2 mV/Div to 10 V/Div.
  • Displacement range
    ±4 Divisions
  • Trigger
    PC USB DSO Acute DS-1202
  • Trigger
    Channel 1, Channel 2, Ext, Video
  • Signal system and line/field frequency (Video triggering mode)
    Support the NTSC, PAL and SECAM broadcasting systems of any field or line frequency.
  • Measurement
    PC USB DSO Acute DS-1202
  • Cursor measurement
    Manual, Track and Auto Measure modes
  • Auto measurement
    Vpp, Vamp, Vmax, Vmin, Vhigh, Vlow, Vavg, Vrms, Frequency, Period, +Width, -Width, +Duty, -Duty