The network simulation (LISN) Rohde & Schwarz HM6050 is used as a reproduction of supply networks in order to be able to carry out the line-bound interference emissions as part of measurements and tests for electromagnetic compatibility (EMC).
The HM6050 suppresses high-frequency interference from the supply network, establishes a standardized impedance for the device under test, and decouples the high-frequency radio interference voltages from the device under test in order to be able to supply it to a spectrum analyzer or EMI receiver.
The R&S® HM6050 is a single-phase V-network simulation for the frequency range from 9 kHz to 30 MHz (according to CISPR 16) and is suitable for maximum currents up to 16 A.
Specifications | R&S® HM6050 |
---|---|
Frequency Range | 9 kHz - 30 MHz |
Impedance | Z = 50 Ω II (50 µH + 5 Ω), Error <20% (VDE 876T1) |
Max. Current | 16 A |
Mains Voltage | 230 V / 50 to 60 Hz, Cat II |
Artificial Hand | 220 pF + 511 Ω |
Protective Earth (selectable) | 50 µH || 50 Ω |
Transient Limiter | R&S® HM6050 |
---|---|
Frequency Range | 150 kHz - 30 MHz |
Transmission Loss | 10 dB (+1,5/-0,5 dB) |
File Size: 780.65 KiB
Release Date: 27.12.2018