The Rogowski probes of the RCP series measure alternating current up to 600 Apk, minimum from 200 mApk, with a bandwidth of 10 Hz to 30 MHz, an accuracy of 1 % and a noise level of less than 2 to 18 mVpp. Within the measuring range, the output signal of the system and the current signal to be measured are always linear, so that the accuracy does not change with the current; the coil contains no magnetic saturation components and no magnetic core or saturation phenomenon, no heating problem; the Rogowski coil contains no ferromagnetic materials and therefore has no hysteresis effect; the phase difference between the output signal and the current waveform is extremely small and can be less than 0.8°.
The RCP models are compact and easy to handle. The RCP500 is suitable for the Micsig UPI multifunction probe interface and requires no additional battery or power supply when used with some new Micsig oscilloscopes. It can also be used with used with the Micsig PA05 adapter to adapt it to oscilloscopes from other manufacturers. The RCP300-XS and RCP600-XS models have a standard BNC interface and have a DC 12 V connection. The RCP models can measure current signals with complex waveforms, such as transient inrush currents from power devices, sinusoidal currents from three-phase currents of three-phase power supply systems, harmonic components of measured currents, current measurements of IGBTs and MOSFETs, etc.
Model | RCP500 | RCP300-XS | RCP600-XS |
---|---|---|---|
Bandwidth | 15 Hz - 300 kHz (-3 dB) | 10 Hz - 30 MHz | 10 Hz - 30 MHz |
Current range | 200 mApk - 500 Apk | 200 mApk - 300 Apk | 200 mApk - 600 Apk |
Output connector | BNC / UPI | BNC | BNC |
Output sensitivity | 10 mV/A | 20 mV/A | 10 mV/A |
Typical accuracy | 1% | 1% | 1% |
Max. voltage | AC 10 kVRMS (1 min, 50 Hz/60 Hz, Rogowski coil part only) | AC 2 kVRMS (1 min, 50 Hz/60 Hz, Rogowski coil part only) | AC 2 kVRMS (1 min, 50 Hz/60 Hz, Rogowski coil part only) |
Output noise | 2 mVRMS | < 18 mVRMS | < 12 mVRMS |
Conductor under test diameter | ≤50 mm | ≤25 mm | ≤25 mm |
Power supply | Micsig UPI multi-function interface, adaptor (USB power) | 12 V DC | 12 V DC |
Coil to integrator cable length | 2 m (customizable) | 1.5 m (customizable) | 1.5 m (customizable) |
Integrator dimensions (mm) | 37 x 22 x 82 | 70 x 40 x 17 | 70 x 40 x 17 |
Rogowski coil | Inner diameter 50 mm (customizable), coil thickness approx. 6 mm | Inner diameter 25 mm (customizable), coil thickness approx. 1.6 mm | Inner diameter 25 mm (customizable), coil thickness approx. 1.6 mm| |
Language: German, English
File Size: 946.65 KiB
Release Date: 04.12.2023
Language: English
File Size: 332.03 KiB
Release Date: 19.12.2023