Innovative Tools. Excellent Service.

RF Current Monitoring Probes

18 of 18 Article

TekBox TBESDT1

The TBESDT1 ESD-Target is a current sensing transducer to verify ESD-Simulators. It is used to take measurements compliant with IEC 61000-4-2 up to 4 GHz.

SPECIFICATIONS

  • Compliance: IEC 61000-4-2
  • Resistance: 2.08 Ω ± 1%
  • Transfer impedance: 2 V/A - 0.2 V/A with 20 dB attenuator
  • Frequency range: DC – 4 GHz, < ± 0.5 dB up to 1 GHz, < ± 1.2 dB up to 4 GHz
  • Max. pulse amplitude: ± 30 kV
2 years warranty

No.: TBESDT1

with FREE shipping within the EU! Shipping costs outside EU
in 11-30 days after order in stock.
1,490.- €
net (VAT Details)
1,773.10 €
incl. 19% VAT

TekBox TBCP1-200

RF current monitoring probe for measuring in the range of 10 kHz to 200 MHz.

  • Aperture diameter: 25 mm
  • Outside diameter: 76 mm
  • Height: 31 mm
  • Weight: 320 g
  • Connector type: N female
  • Transfer impedance: 3 to 17 dBΩ
  • Max. primary current (DC – 400 Hz): 80 A
  • Max. primary current (RF): 3 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP1-200
EAN: 8936120670118

with FREE shipping within the EU! Shipping costs outside EU
in Stock
325.- €
net (VAT Details)
386.75 €
incl. 19% VAT

TekBox TBCP1-250

RF current monitoring probe for measuring in the range of 30 kHz to 250 MHz.

  • Aperture diameter: 25 mm
  • Outside diameter: 76 mm
  • Height: 31 mm
  • Weight: 320 g
  • Connector type: N female
  • Transfer impedance: 0 to 18 dBΩ
  • Max. primary current (DC – 400 Hz): 80 A
  • Max. primary current (RF): 3 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP1-250
EAN: 8936120670125

with FREE shipping within the EU! Shipping costs outside EU
in Stock
325.- €
net (VAT Details)
386.75 €
incl. 19% VAT

TekBox TBCP1-500

RF current monitoring probe for measuring in the range of 30 kHz to 500 MHz.

  • Aperture diameter: 25 mm
  • Outside diameter: 76 mm
  • Height: 31 mm
  • Weight: 320 g
  • Connector type: N female
  • Transfer impedance: -6 to 20 dBΩ
  • Max. primary current (DC – 400 Hz): 80 A
  • Max. primary current (RF): 3 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP1-500
EAN: 8936120670248

with FREE shipping within the EU! Shipping costs outside EU
in Stock
420.- €
net (VAT Details)
499.80 €
incl. 19% VAT

TekBox TBCP1-CAL

The Tekbox TBCP1-CAL calibration device can be used to measure the transfer impedance of Tekbox TBCP1 RF probes in conjunction with a spectrum analyser or a vector network analyser. with a spectrum analyser or a vector network analyser. The calibration device is compatible with all TBCP1 models, e.g. the TBPCP1-20100, and is used exclusively as a calibration instrument. Each Tekbox RF transducer is supplied together with a corresponding calibration sheet, which shows the values of insertion loss and the transfer impedance as a function of the frequency.

2 years warranty

No.: TBCP1-CAL

with FREE shipping within the EU! Shipping costs outside EU
in 11-30 days after order in stock.
545.- €
net (VAT Details)
648.55 €
incl. 19% VAT

TekBox TBCP2-250

RF current monitoring probe for measuring in the range of 30 kHz to 250 MHz.

  • Aperture diameter: 32 mm
  • Outside diameter: 73 mm
  • Height: 20 mm
  • Weight: 320 g
  • Connector type: N female
  • Transfer impedance: 0 to 14 dBΩ between 100 kHz and 250 MHz
  • Max. primary current (DC – 400 Hz): 80 A
  • Max. primary current (RF): 3 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP2-250
EAN: 8936120670354

with FREE shipping within the EU! Shipping costs outside EU
in Stock
675.- €
net (VAT Details)
803.25 €
incl. 19% VAT

TekBox TBCP2-500

RF current monitoring probe for measuring in the range of 30 kHz to 600 MHz.

  • Aperture diameter: 32 mm
  • Outside diameter: 73 mm
  • Height: 20 mm
  • Weight: 320 g
  • Connector type: N female
  • Transfer impedance: 0 to 18 dBΩ between 100 kHz and 500 MHz
  • Max. primary current (DC – 400 Hz): 80 A
  • Max. primary current (RF): 3 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP2-500
EAN: 8936120670385

with FREE shipping within the EU! Shipping costs outside EU
in Stock
745.- €
net (VAT Details)
886.55 €
incl. 19% VAT

TekBox TBCP2-750

RF current monitoring probe for measuring in the range of 30 kHz to 800 MHz.

  • Aperture diameter: 32 mm
  • Outside diameter: 73 mm
  • Height: 20 mm
  • Weight: 320 g
  • Connector type: N female
  • Transfer impedance: 0 to 20 dBΩ between 100 kHz and 750 MHz
  • Max. primary current (DC – 400 Hz): 80 A
  • Max. primary current (RF): 3 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP2-750
EAN: 8936120670392

with FREE shipping within the EU! Shipping costs outside EU
in Stock
795.- €
net (VAT Details)
946.05 €
incl. 19% VAT

TekBox TBCP2-30K400

RF current monitoring probe for measuring in the range of 10 kHz to 500 MHz.

  • Aperture diameter: 32 mm
  • Outside diameter: 73 mm
  • Height: 20 mm
  • Weight: 320 g
  • Connector type: N female
  • Transfer impedance: 0 to 20 dBΩ between 30 kHz and 400 MHz
  • Max. primary current (DC – 400 Hz): 25 A
  • Max. primary current (RF): 2 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP2-30K400

with FREE shipping within the EU! Shipping costs outside EU
in Stock
731.73 €
net (VAT Details)
870.76 €
incl. 19% VAT

TekBox TBCP2-CAL

The Tekbox TBCP2-CAL calibration device can be used to measure the transfer impedance of Tekbox TBCP2 RF probes in conjunction with a spectrum analyser or a vector network analyser. with a spectrum analyser or a vector network analyser. The calibration device is compatible with all TBCP2 models and is used exclusively as a calibration instrument. Each Tekbox RF transducer is supplied together with a corresponding calibration sheet, which shows the values of insertion loss and the transfer impedance as a function of the frequency.

2 years warranty

No.: TBCP2-CAL

with FREE shipping within the EU! Shipping costs outside EU
in 11-30 days after order in stock.
548.- €
net (VAT Details)
652.12 €
incl. 19% VAT

TekBox TBCP3-1000

RF current monitoring probe for measuring in the range of 30 kHz to 1 GHz.

  • Aperture diameter: 17 mm
  • Outside diameter: 52 mm
  • Height: 14 mm
  • Weight: 55 g
  • Connector type: SMA female
  • Transfer impedance: 20 dBΩ
  • Max. primary current (DC – 400 Hz): 30 A
  • Max. primary current (RF): 4 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP3-1000
EAN: 8936120670408

with FREE shipping within the EU! Shipping costs outside EU
in Stock
635.- €
net (VAT Details)
755.65 €
incl. 19% VAT

TekBox TBCP3-CAL

The Tekbox TBCP3-CAL calibration device can be used to measure the transfer impedance of Tekbox TBCP3 RF probes in conjunction with a spectrum analyser or a vector network analyser. with a spectrum analyser or a vector network analyser. The calibration device is compatible with all TBCP3 models and is used exclusively as a calibration instrument. Each Tekbox RF transducer is supplied together with a corresponding calibration sheet, which shows the values of insertion loss and the transfer impedance as a function of the frequency.

2 years warranty

No.: TBCP3-CAL

with FREE shipping within the EU! Shipping costs outside EU
in 11-30 days after order in stock.
548.- €
net (VAT Details)
652.12 €
incl. 19% VAT

TekBox TBCP4-250

RF current monitoring probe for measuring in the range of 10 kHz to 250 MHz.

  • Aperture diameter: 32 mm
  • Outside diameter: 73 mm
  • Height: 20 mm
  • Weight: 320 g
  • Connector type: N female
  • Transfer impedance: 14 dBΩ
  • Max. primary current (DC – 400 Hz): 80 A
  • Max. primary current (RF): 3 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP4-250
EAN: 8936120670347

with FREE shipping within the EU! Shipping costs outside EU
in Stock
405.- €
net (VAT Details)
481.95 €
incl. 19% VAT

TekBox TBCP4-500

RF current monitoring probe for measuring in the range of 10 kHz to 500 MHz.

  • Aperture diameter: 32 mm
  • Outside diameter: 73 mm
  • Height: 20 mm
  • Weight: 320 g
  • Connector type: N female
  • Transfer impedance: 16 dBΩ
  • Max. primary current (DC – 400 Hz): 80 A
  • Max. primary current (RF): 3 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP4-500
EAN: 8936120670361

with FREE shipping within the EU! Shipping costs outside EU
in Stock
520.- €
net (VAT Details)
618.80 €
incl. 19% VAT

TekBox TBCP4-750

RF current monitoring probe for measuring in the range of 10 kHz to 750 MHz.

  • Aperture diameter: 32 mm
  • Outside diameter: 73 mm
  • Height: 20 mm
  • Weight: 320 g
  • Connector type: N female
  • Transfer impedance: 20 dBΩ
  • Max. primary current (DC – 400 Hz): 80 A
  • Max. primary current (RF): 3 A
  • Max. core temperature: 125 °C
2 years warranty

No.: TBCP4-750
EAN: 8936120670378

with FREE shipping within the EU! Shipping costs outside EU
in Stock
635.- €
net (VAT Details)
755.65 €
incl. 19% VAT

TekBox TBCP4-CAL

The Tekbox TBCP4-CAL calibration device can be used to measure the transfer impedance of Tekbox TBCP4 RF probes in conjunction with a spectrum analyser or a vector network analyser. with a spectrum analyser or a vector network analyser. The calibration device is compatible with all TBCP4 models and is used exclusively as a calibration instrument. Each Tekbox RF transducer is supplied together with a corresponding calibration sheet, which shows the values of insertion loss and the transfer impedance as a function of the frequency.

2 years warranty

No.: TBCP4-CAL

with FREE shipping within the EU! Shipping costs outside EU
in 11-30 days after order in stock.
548.- €
net (VAT Details)
652.12 €
incl. 19% VAT

TekBox TBCP5-150K400

RF current monitoring probe for measuring in the range of 10 Hz to 500 MHz.

  • Characterized frequency range: 10 Hz to 500 MHz, 3 dB bandwidth: 150 kHz to 400 MHz, typ.
  • Transfer impedance: 11 dBΩ (3.5 Ω) in the flat region, typ. (50 Ω load impedance)
  • Insertion impedance: <400mΩ up to 400 MHz (series measurement method)
  • Shunt capacitance: <1 pF (concentric cable with ⌀ 10 mm)
  • Output impedance: 50 Ω (resistive matching)
  • Max. bias current (DC – 400 Hz): 200 A (no influence on transimpedance)
  • Max. primary current (RF): 2 A
  • Max. core temperature: 125 °C
  • Connector type: N female
2 years warranty

No.: TBCP5-150K400

with FREE shipping within the EU! Shipping costs outside EU
in 31-60 days after order in stock.
895.- €
net (VAT Details)
1,065.05 €
incl. 19% VAT

TekBox TBCP5-CAL

The Tekbox TBCP5-CAL calibration device can be used to measure the transfer impedance of Tekbox TBCP5 RF probe in conjunction with a spectrum analyser or a vector network analyser. with a spectrum analyser or a vector network analyser. Each Tekbox RF transducer is supplied together with a corresponding calibration sheet, which shows the values of insertion loss and the transfer impedance as a function of the frequency.

2 years warranty

No.: TBCP5-CAL

with FREE shipping within the EU! Shipping costs outside EU
in 31-60 days after order in stock.
649.- €
net (VAT Details)
772.31 €
incl. 19% VAT