Micsig's CP2100 Series current clamps can measure both DC and AC current and feature a compact design. They have a standard BNC interface for oscilloscopes and multimeters. Two optional measurement ranges are available, as well as automatic demagnetization and zeroing, and visual and audible overload indicators.
| Model | CP2100A | CP2100B |
|---|---|---|
| Bandwidth | DC-800 kHz | DC-2.5 MHz |
| Rise Time | <= 437.5 ns | <= 140 ns |
| Ranges | 10 A/100 A | 10 A/100 A |
| Output Sensitivity | 0.1 V/A (10 A) 0.01 V/A (100 A) | 0.1 V/A (10 A) 0.01 V/A (100 A) |
| DC Accuracy | 3 %+-50 mA (10 A) 4 %+-50 mA (100 A, 500 mA-40 Apk) 15 % (100 A, 40 Apk-100 Apk) | 3 %+-50 mA (10 A) 4 %+-50 mA (100 A, 500 mA-40 Apk) 15% (100 A, 40 Apk-100 Apk) |
| Signal Delay | <150 ns (10 A) <200 ns (100 A) | <150 ns (10 A) <200 ns (100 A) |
| Category | CAT II 600 V / CAT III 300 V | CAT II 600 V / CAT III 300 V |
| Power supply | DC 5 V | DC 5 V |
| Max. conductor diameter | 13 mm | 13 mm |
Language: English
File Size: 3.21 MiB
Release Date: 29.01.2024
Language: English
File Size: 4.53 MiB
Release Date: 18.03.2024
Language: English
Version: 1.8
File Size: 3.90 MiB
Release Date: 18.08.2023