The Micsig CPXX03B current clamps, with a bandwidth of 50/100/150 MHz, offer excellent value for money. They are therefore a good option if you are looking for an affordable current clamp. Thanks to their standard BNC interface, they are compatible with all oscilloscopes. In addition, they offer accurate and easy-to-use AC/DC measurement functions, a range selection of 5 A / 30 A, an overload indicator and undercurrent detection, as well as 1% DC accuracy.
| Specification | CP1503B | CP1003B | CP503B |
|---|---|---|---|
| Bandwidth | 150 MHz | 100 MHz | 50 MHz |
| Rise time | ≤ 2,67 ns | ≤ 3,5 ns | ≤ 7 ns |
| Max. Current Input | 50 Apeak, 30 Arms | 30 Arms, 50 Apeak | 30 Arms, 50 Apeak |
| Range | 5 Arms (5 A) 30 Arms (30 A) | 5 Arms (5 A) 30 Arms (30 A) | 5 Arms (5 A) 30 Arms (30 A) |
| Accuracy (Max continuous current @ DC and 45-66Hz) | ±1% ±1 mA (5 A) ±1% ±10 mA (30 A) | ±1% ±1 mA (5 A) ±1% ±10 mA (30 A) | ±1% ±1 mA (5 A) ±1% ±10 mA (30 A) |
| Lowest measurable current | 1 mA (5 A) 10 mA (30 A) | 1 mA (5 A) 10 mA (30 A) | 1 mA (5 A) 10 mA (30 A) |
| Noise (20 MHz limitation) | ≤400 μArms (5 A) ≤120 μArms (30 A) | <4 mApp (5 A) <30 mApp (30 A) | <4 mApp (5 A) <30 mApp (30 A) |
| Output Sensitivity | 1 V / 1 A (5 A, 1×) 1 V / 10 A (30 A, 10×) | 1 V / 1 A (5 A, 1×) 1 V / 10 A (30 A, 10×) | 1 V / 1 A (5 A, 1×) 1 V / 10 A (30 A, 10×) |
| Power Supply | DC 12 V | DC 12 V | DC 12 V |
| Max. Conductor Diameter | 5 mm | 5 mm | 5 mm |
| Cable length | 1,5 m | 1 m | 1 m |
| Interface | Standard BNC interface | Standard BNC interface | Standard BNC interface |
Language: English
File Size: 912.51 KiB
Release Date: 21.09.2026
Language: English
File Size: 2.10 MiB
Release Date: 21.09.2026
Language: English
File Size: 570.90 KiB
Release Date: 21.09.2026