The TBL0110-2 LISN is a two path 50 Ω // 1 µH LISN characterized from 30Hz – 500 MHz. It is based on the standard ECSS-E-ST-20-07C Rev 1. The standard provides the general schematic of the LISN and allows for some flexibility in component values. The TBL0110-2 implementation aims for use in EMC measurements of small satellites and spacecraft. The LISN does not have an output for conducted emission measurements; instead, it merely functions as a network for line impedance stabilisation. An RF current monitoring probe is used to measure conducted emissions, according to the standard.
The 1µH inductor mimics the typical inductance of the supply wire harness in small spacecraft or satellites.
The LISN is inserted into the power line and power return line of the EUT.
| Model | Impedance | Frequency Range | Path | Max. Current | Max. Voltage | Additional Features |
|---|---|---|---|---|---|---|
| TBL00705-2 | 0.7µH//50Ω | 30 Hz – 500 MHz | 2 | 5A | 60V nominal, Component rating: 100V | 400mΩ serial resistor |
| ТВL0110-2 | 1µH//50Ω | 30 Hz – 500 MHz | 2 | 10A | 60V nominal, Component rating: 100V | 100mΩ serial resistor |
| TBL0225-2 | 2µH//50Ω | 10 Hz – 200 MHz | 2 | 25A | 60V nominal, Component rating: 100V | 100mΩ serial resistor |
| TBOH01 | 5µH//50Ω | 150 kHz – 108 MHz | 1 | 10A | 60V nominal, Component rating: 200V | EOL |
| TBL0510-1 | 5µH//50Ω | 10 kHz – 400 MHz | 1 | 10A | 60V nominal, Component rating: 200V | |
| TBL0550-1 | 5µH//50Ω | 150 kHz – 108 MHz | 1 | 50A | 60V nominal, Component rating: 250V | |
| TBL05100-1 | 5µH//50Ω | 150 kHz – 108 MHz | 1 | 100A | 60V nominal, Component rating: 350V AC@50/60Hz 600V DC | Can be jumpered to various standards |
| TBL05100-1B | 5µH//50Ω | 150 kHz – 108 MHz | 1 | 100A | Component rating: 0-500V @ 50/60 Hz 250V AC @ 400Hz 1000V DC | Can be jumpered to various standards |
| Model | Impedance | Frequency Range | Path | Max. Current | Max. Voltage | Additional Features |
|---|---|---|---|---|---|---|
| TBL5016-1 | 50µH//50Ω (50µH+5Ω)//50Ω | 150 kHz – 30 MHz | 1 | 16A | 250V | can be jumpered 50µH//50Ω or (50µH+5Ω)//50Ω no 250uH pre-filter |
| TBL50100-1 | 50µH//50Ω (50µH+5Ω)//50Ω | 150 kHz – 30 MHz | 1 | 100A | 250V | can be jumpered 50µH//50Ω or (50µH+5Ω)//50Ω no 250uH pre-filter |
| TBL5008-2B | (50µH+5Ω)//50Ω | 9 kHz – 30 MHz | 2 | 8A | 250V AC 50/60 Hz or DC | separate RF outputs enabling LISN-Mate connectivity; Artificial hand connection PE switchable: 50Ω//50µH |
| TBL5008-2C | (50µH+5Ω)//50Ω | 9 kHz – 30 MHz | 2 | 8A | 250V AC 50/60 Hz or DC | Filter/Limiter/Attenuator switchable Artificial hand connection PE switchable: 50Ω//50µH |
| TBL5016-2B | (50µH+5Ω)//50Ω | 9 kHz – 30 MHz | 2 | 16A | 250V AC 50/60 Hz or DC | separate RF outputs enabling LISN-Mate connectivity; Artificial hand connection PE switchable: 50Ω//50µH |
| TBL5016-2C | (50µH+5Ω)//50Ω | 9 kHz – 30 MHz | 2 | 16A | 250V AC 50/60 Hz or DC | Filter/Limiter/Attenuator switchable Artificial hand connection PE switchable: 50Ω//50µH |
| TBL5016-3 | (50µH+5Ω)//50Ω | 9 kHz – 30 MHz | 3 | 16A | 465V/270V | Artificial hand connection PE switchable: 50Ω//50µH |
| TBL5032-3 | (50µH+5Ω)//50Ω | 9 kHz – 30 MHz | 3 | 32A | 465V/270V | Artificial hand connection PE switchable: 50Ω//50µH |
| TBL5063-3 | (50µH+5Ω)//50Ω | 9 kHz – 30 MHz | 3 | 63A | 690V/400V 50Hz/60Hz | Artificial hand connection PE switchable: 50Ω//50µH |
| Model | Impedance | Frequency Range | Path | Max. Current | Max. Voltage | Additional Features |
|---|---|---|---|---|---|---|
| TBLM2 | | 150 kHz – 110 MHz | | | | LISN-Mate |
| TBLDC32-2 | 150 Ohm | 9 kHz – 30 MHz | 2 | 32A | 1000V DC | 150 Ohm DC LISN A, B, Common-Mode Differential-Mode operation |
| TBLVHF-B | 50 Ohm +-10% | 30 MHz – 300 MHz | 2 | 16A | 250V DC – 400 Hz | Balanced VHF LISN |
| TBISN-T4 | 150 Ohm | 150 kHz – 30 MHz | 2 balanced pairs | 250mA | 60V AC, 100V DC | 2 pcs D-Sub 25 to RJ45 adapter |
Language: English
Version: V1.1
File Size: 612.28 KiB
Release Date: 31.10.2023
Language: German
Version: V1.7
File Size: 402.40 KiB
Release Date: 12.10.2022
This document focusses on measurement equipment and methods, limits and the relevant standards of conducted noise measurement on the power supply lines of products. The document tries to reduce the details to those necessary to carry out pre-compliance measurements in house with modest equipment.