In the past, if you wanted an oscilloscope with exceptional performance, you could expect to pay a premium. Not anymore. The InfiniiVision 6000 X-Series oscilloscopes combine price and performance to set a new standard in the portable oscilloscope world. Imagine a 6 GHz bandwidth oscilloscope that sees and triggers on everything, helps you visualize complex waveforms and grows with your projects.
The new InfiniiVision 6000 X-Series’ 450,000 waveforms-per-second update rate coupled with the exclusive hardware-based zone touch trigger provide unprecedented visualization power to help you isolate your waveforms of interest. Add a whole new depth of “visualization” to your designs with features like the industry’s first 12-inch multi-touch capacitive touch screen with gesture support, the first embedded-OS-oscilloscope optional jitter/real-time eye analysis, and standard histogram and color grade.
The Keysight DSOX6002A has 7-in-1 integration, combining digital channels, serial protocol analysis, a built-in dual-channel waveform generator, frequency response analysis, built-in digital multimeter, and built-in 10-digit counter with totalizer. It also integrates multi-language voice control for the first time in an oscilloscope.
The InfiniiVision 6000 X-Series sets the new standard.
Features | DSOX6002A | DSOX6004A |
---|---|---|
Channel | 2 | 4 |
Bandwidth | 1 GHz - 6 GHz | 1 GHz - 6 GHz |
Sample rate | 20 GSa/s half channels 10 GSa/s full channels | 20 GSa/s half channels 10 GSa/s full channels |
Waveform capture rate | 450000 wfms/s | 450000 wfms/s |
Memory depth | 4 Mpts half channels 2 Mpts all channels | 4 Mpts half channels 2 Mpts all channels |
You will find the specifications of the InfiniiVision 6000X X-series here.
InfiniiVision DSOX6000A X (2 channel) (MSO Sets) | Bandwidth | Waveformgenerator | Logic analyzer |
---|---|---|---|
DSOX6002A | 1 GHz (basic) 2.5 GHz (DSOX6B10T252BW) 4.0 GHz (DSOX6B10T402BW) 6.0 GHz (DSOX6B10T602BW) | Option (DSOX6WAVEGEN2) | Option (DSOX6MSO) |
MSOX6002A | 1 GHz (basic) 2.5 GHz (DSOX6B10T252BW) 4.0 GHz (DSOX6B10T402BW) 6.0 GHz (DSOX6B10T602BW) | Option (DSOX6WAVEGEN2) |
InfiniiVision DSOX6000A X (4 channel) (MSO Sets) | Bandwidth | Waveformgenerator | Logic analyzer |
---|---|---|---|
DSOX6004A | 1 GHz (basic) 2.5 GHz (DSOX6B10T254BW) 4.0 GHz (DSOX6B10T404BW) 6.0 GHz (DSOX6B10T604BW) | Option (DSOX6WAVEGEN2) | Option (DSOX6MSO) |
MSOX6004A | 1 GHz (basic) 2.5 GHz (DSOX6B10T254BW) 4.0 GHz (DSOX6B10T404BW) 6.0 GHz (DSOX6B10T604BW) | Option (DSOX6WAVEGEN2) |
The 6000 X-Series offers 16 optional, integrated and upgradable digital channels. Digital content is everywhere in today’s designs and traditional 2 and 4 channel oscilloscopes do not always provide enough channels for the job at hand. With an additional 16 integrated digital channels, you now have up to 20 channels of time-correlated acquisition and viewing on the same instrument. In addition to offering powerful triggering across the analog and digital channels, this also gives you additional channels to use for serial decode and triggering. If you buy a 2 or 4 channel DSO, you can upgrade it at any time to an MSO with a software license and 16-channel logic probe.
The 6000 X-Series offers an integrated 20 MHz function/arbitrary waveform generator, available with modulation support. The function generator provides stimulus output of sine, square, ramp, pulse, DC, Sinc (x), exponential rise/fall, cardiac, Gaussian Pulse and noise waveforms. The modulation feature supports AM, FM, and FSK modulations with modulation shapes of sine, square, and ramp. The generator can output a continuous or a single-shot waveform. With AWG functionality, you can store waveforms from analog channels or reference memory to the arbitrary memory and output from WaveGen.
Frequency Response Analysis (FRA) is an often-critical measurement used to characterize the frequency response (gain and phase versus frequency) of a variety of today’s electronic designs, including passive filters, amplifier circuits, and negative feedback networks of switch mode power supplies (loop response). InfiniiVision 6000 X-Series oscilloscopes use the oscilloscope’s built-in waveform generator (WaveGen) to stimulate the circuit under test at various frequency settings and capture the input and output signals using two oscilloscope channels. At each test frequency, the oscilloscope measures, computes, and plots gain (20LogVout/Vin) and phase logarithmically.
Whether you are performing pass/fail tests to specified standards in manufacturing or testing for infrequent signal anomalies, mask/limit testing can be a valuable productivity tool. The 6000 X-Series features powerful hardware-based mask testing that can perform up to 270,000 tests per second. You can select multiple test criteria, including the ability to run tests for a specific number of acquisitions, a specified time, or until detection of a failure.
Segmented memory works in conjunction with serial protocol decode. For example, by setting the trigger condition to “CAN serial bus error,” segmented memory captures and stores only CAN error packets and stitches together each segment for easy viewing. You can quickly compare time tags in the event lister to discover time intervals between errors.
In addition to triggering on and decoding low-speed, full-speed, and hi-speed USB 2.0 signals (hi-speed trigger & decode require a 1.0 or 1.5 GHz model), the optional USB Software Package (D6000USBA) also supports USB 2.0 signal quality testing (hi-speed tests require the 1.5 GHz model). The USB 2.0 signal quality test with HTML pass/fail report generation includes eye-diagram mask testing, jitter analysis, EOP bit-width, signaling rate, edge monotonicity, and rise/fall times; all based on official USB-IF algorithms embedded in the oscilloscope.